SMART 3-R
The SMART3-R detector is ideal for applications in light industry and machine rooms, with a buzzer and LED indicator providing rapid alert to the presence of explosive, toxic and refrigerant gases.
Where to BuyWhat are you looking for?
The SMART3-R detector is ideal for applications in light industry and machine rooms, with a buzzer and LED indicator providing rapid alert to the presence of explosive, toxic and refrigerant gases.
Where to BuyDesigned for machine rooms, laboratories and unclassified areas, the SMART3-R detector provides detection of explosive, toxic and refrigerant gases in safe (unclassified) areas.
With a 4-20 mA output, an RS485 communication bus and a 3-relay board, the circular LED indicator on the front displays the status of the instrument and an internal buzzer is activated in the event of a fault and/or alarm.
The instrument is controlled and calibrated via a keypad with STS/CKD+ display, with a protection rating of IP42. On request, the SMART3-R can be supplied in a version with an additional remote head and a 5m 6-pole cable included.
SMART3-R complies with the following regulations:
With catalytic sensor | With catalytic sensor | With catalytic sensor | |
Size | Box: 120 x 120 x 52 mm Cover: 130 x 130 x 22 mm Remote head box: 106 x 106 x 56 mm |
||
Weight | Detector: 0.45kg Remote head: 0.3kg |
||
Enclosure material | Polycarbonate | ||
Ingress protection | IP42 | ||
Connection | 2 entries with M20 cable glands 6 optional entries for M16 cable glands |
||
Power | 12-24 Vdc or 90-240Vac | ||
Electrical output | 3 relays; RS485 serial output, 4-20 mA analogue output (only for 12-24 Vdc version) |
||
Operating temperature | -40 / +60°C -40 / +50°C 230V version |
-40 / +60°C (-10 / +50°C infred sensor for ppm refrigerant gases) -40 / +50°C 230V version (-10 / +50°C infred sensor for ppm refrigerant gases) |
-30 / +50°C |
Humidity | 0 / 95% RH non condensing | 15 / 90% RH non condensing | |
Compliance | EMC EN 61000-6-3:2007 + A1:201; EN 50270:2015 Electrical safety (90-240 Vac version) EN 61010-1: 2010 / A1: 2019 Refrigeration Standards EN 378-3; EN 14624; EN 50676; IEC 60335-2-40 Annex LL; ISO 5149-3; F-Gas Regulation |
Read about Crowcon’s Privacy and Cookie policy here. If you change your mind, you can unsubscribe at any time
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.