Dove acquistareAvailable with a choice of sensor technology to suit your needs, the Gasman is an ultra-lightweight single gas detector, designed for use in the toughest environments. Its compact and lightweight design makes it the ideal choice for industrial gas detection, in oil and gas, chemical plants (with exotic gases), steel works (special CO sensor), hospitality (CO2), renewable energy (hydrogen) and waste and water works. Also available with our long-life O2 sensor (LLO2), for the accurate detection of oxygen depletion and enrichment, which comes with a 5 year warranty.
Weighing just 130g, it is extremely durable, with high impact resistance and dust/water ingress protection, loud 95 dB alarms, a vivid red/ blue visual warning, single-button control and an easy-to-read, backlit LCD display for clear insights and warnings. Data and event logging are available as standard, and there is a built-in 30-day advance warning when calibration is due. Gasman is also available in a safe area CO2 version offering 0-5% carbon dioxide measurement.
Garanzia di 5 anni sul sensore
Ultra leggero
Funzionamento con un solo pulsante
MPS™ & LLO2 sensor options
Moduli sensore intelligenti intercambiabili
Robusto
- Tough polycarbonate housing – protects you in the harshest environments
- Water and dust resistant to IP65
- Full over moulding – high impact resistance
Effective Warning
- Two levels of instantaneous alarm and time-weighted average (TWA) alarms for toxic versions
- 95dB audible alarm for loud, clear warnings even in noisy environments, ensuring you can respond quickly to hazards
- Vivid twin red/blue LED visual alarm for visibility of any warning
- Where ambient noise is high, a vibrating alarm is triggered, to guarantee awareness when on your person
Flessibile
- Fully interchangeable intelligent sensor modules for precise, single-gas detection
- Real-time TWA and peak display options
- Rechargeable versions for all gas types
- Non-rechargeable versions providing an affordable solution for detection of oxygen and toxic gases
Amico dell'utente
- Simple single-button operation making it easy-to-use even whilst wearing gloves
- Backlit display for easy reading of gas diagnostics and operating status, even in poorly lit conditions
- Weighing just 85g for toxic gas detection versions, it’s ultra lightweight making it no bother to carry at all times
Dimensione | 90 x 48 x 24 mm (3,5 x 1,9 x 0,95 ins) |
Peso | Infiammabile: 138g (4,9oz) Tossico: 85g (3oz) Ossigeno: 129g (4,6oz) Monossido di carbonio: 139g (4,9oz) |
Tempi di risposta tipici (T90) | Infiammabile: 20s Infiammabile (MPS): 17s Gas tossico: 20s Ossigeno: 10s Ossigeno (a lunga durata): 10s |
Allarmi | Audible: 95dB; Multiple alarm options let you select distinctive tones for different alarm levels Visible: Dual colours red/ blue flashing LEDs in a gas hazard Internal vibrating alarm |
Display | LCD personalizzato con retroilluminazione, con visualizzazione della concentrazione di gas. Simboli grafici per la batteria (con indicazione proporzionale del tempo di funzionamento rimanente) e per la modalità di visualizzazione. Indicazione all'avvio della scadenza della calibrazione entro 30 giorni, della calibrazione scaduta o della necessità di assistenza. Visualizzazione normale: Livelli di concentrazione del gas in tempo reale Richiamo del display: Letture di picco e TWA |
Registrazione dei dati | Registrazione dati temporizzata completa con frequenza di campionamento regolabile, impostata di default su una frequenza dati di 1 minuto. 900 ore di memorizzazione a intervallo di 1 minuto (54.000 registri), >4800 eventi |
Batteria | Batteria al litio ricaricabile per tutti i tipi di gas Batteria al litio non ricaricabile per sostanze tossiche e ossigeno (esclusoCO2) |
Tempo di funzionamento* | Ricaricabile con MPS: >3 giorni Ricaricabile: 12 ore minimo per unità infiammabili Non ricaricabile: Fino a 2 anni |
Campionamento | Aspiratore manuale opzionale |
Temperatura di esercizio** | Da -20°C a +65°C (da -4°F a +149°F) |
Umidità | 5 - 95% RH 0 - 99% RH (O2 LL MPS) |
Protezione dall'ingresso | IP65 |
Approvazioni | Europe: Toxic or O2: ATEX II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +65°C) BASEEFA04ATEX0384 Flammable: ATEX II 2G Ex ia db IIC T4 Gb (-20°C ≤ Ta ≤ +65°C) BASEEFA04ATEX0383Flammable (MPS): ATEX II 1G Ex ia IIC T4 Ga (-20°C ≥Ta ≥ +65°C) BASEEFA04ATEX0383 International: Toxic or O2: IECEx Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +65°C) BAS05.0039 Flammable: IECEx Ex db ia IIC T4 Gb (-20°C ≤ Ta ≤ +65°C) BAS05.0038 North America: CSA Class 1 Groups A,B,C,D Division 1 |
Standard | Europa: EN60079-0, EN60079-11, EN60079-1, ATEX 2014/34/EU Nord America: CSA22.2, 152EN50270, EN50271, EN61779 |
Interfaccia PC | Collegamento RS232 dal modulo di interfaccia nel caricatore Convertitore RS232/USB disponibile |
Calibrazione | Gasman can be routinely calibrated using Portables PC software or by using Checkbox IMH |
Accessori |
Gasman is supplied with an integral alligator clip. Accessori opzionali: Gas test kit, Gasman external filter, leather carry case, single way charger, charger interface software and communication kit (excluding PSU), 5 way multi-charger |
Crowcon Connect è compatibile? | Sì |
*Il tempo di funzionamento dipende dal tipo di funzionamento e dal verificarsi degli allarmi. Allarmi frequenti o di lunga durata e l'uso del segnale acustico di sicurezza opzionale riducono la durata della batteria.
**I sensori tossici e di ossigeno non sono adatti al funzionamento continuo ad alte temperature. Consultare Crowcon se le temperature di esercizio possono superare i 40°C (104°F) per periodi prolungati.
Gli intervalli e gli allarmi richiesti variano a seconda del Paese e dell'applicazione e possono essere configurati in base alle esigenze. Per ogni canale di gas possono essere impostati due livelli di allarme istantanei. Le unità tossiche dispongono anche di allarmi di media ponderata nel tempo (TWA).
La calibrazione dei gas infiammabili è disponibile di serie per metano, propano, butano, pentano, idrogeno e
etilene.
Gasman is also available in a safe area CO2 version offering 0-5% carbon dioxide measurement.
Gas | Gamma | Allarme standard (Regno Unito) |
Ammoniaca (NH3) | 0-1000 ppm | 25 ppm |
Monossido di carbonio (CO) | 0-1500 ppm | 20 ppm |
Anidride carbonica (CO2) | 0-5% vol. | 0,5% vol. |
Carbon Monoxide (H2 filtered) |
0-500ppm | 20ppm |
Cloro (Cl2) | 0-20 ppm | 0,3 ppm |
Biossido di cloro (CIO2) | 0-1 ppm | 0,1 ppm |
Ossido di etilene (ETO) | 0-10 ppm | 3 ppm |
Infiammabile Vero LEL (MPS) | 0-100% LEL | 20% LEL |
Infiammabile | 0 - 100% LEL | 20% LEL |
Fluoro (F2) | 0-1 ppm | 0,5 ppm |
Idrogeno (H2) | 0-2000 ppm | N/D |
Cianuro di idrogeno (HCN) | 0-25 ppm | 5 ppm |
Fluoruro di idrogeno (HF) | 0-10 ppm | 1 ppm |
Solfuro di idrogeno (H2S) | 0-250ppm | 5 ppm |
Ossido nitrico (NO) | 0-100 ppm | 25 ppm |
Biossido di azoto (NO2) | 0-20 ppm | 1 ppm |
Ossigeno (O2), a lunga durata | 0-25% vol. | 19,5% / 23,5% vol. |
Ossigeno (O2) | 0-25% vol. | 19,5% / 23,5% vol. |
Ozono (O3) | 0-1 ppm | 0,1 ppm |
Fosfina (PH3) | 0-5 ppm | 0,1 ppm |
Phosgene (COCL2) | 0-1 ppm | 0,1 ppm |
Biossido di zolfo (SO2) | 0-20 ppm | 1 ppm |
accessori
Gasman External Filter C02132
Per l'impiego in ambienti ad alto contenuto di polvere, come le acciaierie.
Custodia in pelle C01983
Consente di indossare l'unità su una cintura o con una tracolla.
Kit per il test dei gas C01892
Consente la calibrazione e il test del gas. Include - Regolatore a grilletto con tubo di alimentazione del gas da 1 m, tappo di flusso, magnete e...
Caricatore monodirezionale C01941
Culla di ricarica. Selezionare l'opzione di alimentazione.
Cavo di ricarica per presa accendisigari del veicolo C01296
Utilizzare le basi di ricarica con ingresso a 12 V CC C01941 o C01940.
Gasman interface kit C011305
Gasman Interface Kit includes single way charger/interface, USB-RS232 adaptor, PC lead and multi-region PSU
5 Way Multi-Charger C01951
To recharge 5 Gasman units at once. Select power supply option.
Caricatore interfaccia PC monodirezionale C01940
Culla di ricarica con connessione all'interfaccia PC per consentire il download dei dati e la configurazione dello strumento. Richiede un cavo PC F-F (E07532) e un...
DOWNLOADS
Video
Schermata iniziale
Includes: What the Gasman Home Screen looks like and understanding the icons. Duration: 28 seconds
Retroilluminazione
Include: Come attivare la retroilluminazione per la visualizzazione in condizioni di scarsa illuminazione. Durata: 19sec
Gasman Field Calibration
Includes: How to calibrate the Crowcon Gasman using a flow plate. Duration: 1m:57secs
Gasman CO Activation
Includes: Switching Gasman CO on and sensor zero function. Duration: 52secs
TWA
Includes: How to view average gas exposure measurements on a Gasman (TWA = Time Weighted Average). Duration: 46secs
Gasman Manual Zero
Include: Come eseguire l'azzeramento del sensore in aria pulita. Durata: 50sec
Gasman Peak Mode
Include: Come commutare il display per visualizzare le letture del livello di picco del gas. Durata: 31sec.
Esplora i prodotti correlati
Abbonatevi per ricevere gli ultimi approfondimenti
nella vostra casella di posta elettronica.
Leggi le informazioni su Crowcon Privacy e Politica sui cookie qui. Se cambiate idea, potete annullare l'iscrizione in qualsiasi momento.