Size |
W135 x H80 x D35 mm (5.3 x 3.1 x 1.4in) |
Weight |
282g (9.9oz) |
Durability |
Drop tested to 4m onto concrete |
Alarms |
Audible >95dB Bright red/blue visual LEDs Integrated vibrating alert |
Display |
Front mounted, backlit. Optional 180° flip for easy viewing whilst worn |
Logging |
130 hours of data logging; Up to 3500 events |
Battery |
Rechargeable Li-ion Up to 18 hour typical runtime (Standard sensor option)Up to 35 hours runtime (MPS and LLO2 options) 5.5 hour recharge |
Operating temperature |
-20°C to +55°C (-4°F to +131°F)* |
Humidity |
10 to 95% RH @ 40°C non-condensing |
Ingress protection |
Independently tested to IP65 and IP67 |
Approvals |
ATEX and UKCA II 1 G Ex ia IIC T4 Ga -20°C ≤ Ta ≤ +55°C (T4 Type 1)
IECEx Ex ia IIC T4 Ga -20°C ≤ Ta ≤ +55°C (T4 Type 1)
UL and cUL: Use in hazardous locations Class 1 Div 1 groups A,B,C,D only as to intrinsic safety
MED Directive 2014/90/EU (Pending)
|
Interface |
USB communications lead |
Accessoires |
Included with T4:
Integrated alligator clip and tethering loop
Bump/Calibration plate
Available separately: Single unit cradle charger, 10 unit cradle charger; Vehicle charger Clip on filter plate for sensor protection in dusty environments I-Test automated bump and calibration station
|
Crowcon Connect Compatible? |
Yes |
* Toxic and oxygen sensors are not rated for continuous operation above 50°C (122°F)