It is important to note that whereas portable gas detection instruments measure and alarm at the TWA levels, instantaneous alarms are included to provide early warning of an exposure to dangerous gas concentrations. Workers are often under risk of gas exposure in situations where atmospheres cannot be controlled, such as in confined space entry applications where alarming at TWA values would be inappropriate.

You must perform your own risk assessment to ensure alarms are set to appropriate levels for your application and in accordance with local legislation and practices.

The following data has been extracted from EH40 and EH40 for some common toxic gases:

Workplace Exposure Limits:
  WORKPLACE EXPOSURE LIMITS
(EH40/2005)
OSHA-PELs
SUBSTANCE CHEMICAL FORMULA LTEL (8hr TWA) PPM STEL (15 minute TWA) PPM LTEL (8hr TWA) PPM
Ammoniac  NH3  25  35  50
Arsine  AsH3  0.05  –  0.05
Brome  Br2  0.1  0.2  0.1
Dioxyde de carbone  CO2  5000  15000  5000
Monoxyde de carbone  LE CO  20  100  50
Chlore  Cl2  –  0.5  1 ceiling *
Dioxyde de chlore  ClO2  0.1  0.3  0.1
Diborane  B2H6  0.1  –  0.1
Ethylene Oxide ETO  C2H40  5  –  1
Fluor  F2  1  1  0.1
Germane  GeH4  0.2  0.6  –
Cyanure d'hydrogène  HCN  0.9  4.5  10
Chlorure d'hydrogène  HCI  1  5  5 ceiling*
Fluorure d'hydrogène  HF  1.8  3  3
Sulfure d'hydrogène  H2S  5  10  20 ceiling*
Nitrous Oxide  N2O  100  –  –
Oxyde nitrique  NO  2  –  25
Dioxyde d'azote  NO2  0.5  1  5 ceiling*
Ozone  O3  –  0.2  0.1
Phosgene  COCl2  0.02  0.06  0.1
Phosphine  PH3  0.1  0.2  0.3
Silane  SiH4  0.5  1  –
Dioxyde de soufre  SO2  0.5  1  5

*C – Ceiling Limit