TXGARD IS+
TXgard IS+ is an Intrinsically Safe (I.S.) toxic and oxygen gas detector with local LCD display. Toxic gas detectors are ATEX certified for use in Zone 0,1 or 2 hazardous areas and also UL and cUL certified for use in Division 1 or 2 hazardous areas, with a wide choice of sensors available for use in a variety of applications.
Dónde comprarThis Intrinsically Safe (I.S) gas detector is designed to operate safely in environments where flammable gases, vapours, or combustible dust may be present, making it the perfect choice for hazardous environments.
With an extensive range of electrochemical sensors for oxygen and toxic gas detection, the Txgard IS+ provides multi-gas detection with an uncompromising approach to safety. Rugged and reliable, the Txgard IS+ is made from tough carbon loaded nylon, with ingress protection to IP65 as standard.
Calibration can be performed locally without the need for hot work permits, as local display and buttons enable calibration without opening the junction box, minimising operational down-time.
With flexible output options, simple parts replacement and long-life sensors designed to keep interruption to on-site activity to a minimum, the Txgard IS+ offers comprehensive gas detection with low ownership costs.
Intrinsically Safe detector
Wide range of electrochemical sensors
Rugged and reliable
Non-intrusive calibration
Flexible output options
Non-Intrusive Calibration
- Calibration can be performed locally without the need for hot work permits, minimising operational down-time
- Local display and buttons enable calibration without opening the junction box
- No opening of the detector is required for calibration, meaning there is no need to declassify the area for calibration
Flexible Output Options
- 4-20mA current sink works with a wide selection of control panels
- 2-wire format
Reliable Detection Across a Wide Range of Gases
- Extensive range of electrochemical sensors for oxygen and toxic gas detection
- Intrinsically Safe (I.S.) detector, ATEX certified for use in Zone 0,1 or 2 hazardous areas & UL and cUL certified for Division 1 or 2 hazardous areas
- Made from tough carbon loaded nylon
- Ingress protection to IP65 as standard
Low Cost of Ownership
- Non-intrusive one-man calibration makes the device easy to operate and maintain
- Long life sensors help keep interruption to on-site activity to a minimum
- Simple parts replacement reduces lifetime cost
Size | 160 x 123 x 92mm (6.3 x 4.8 x 4.5ins) |
Weight | 0.7kg (1.5lbs) |
Ingress protection | IP65 |
Enclosure material | Junction box: Carbon loaded nylon Sensor housing: ABD Plastic |
Power | 8-32Vdc, 4-20mA loop-powered |
Cable entries | 1 x M20 or 1/2” NPT with adaptor |
Operating temperature | -20°C to +55°C (-4°F to 132°F) * |
Humidity | 15 to 90% RH non-condensing |
Display | 2-Line, 16 character LCD |
Calibration method | Via push-buttons |
Electrical output | 2 wire 4-20mA sink |
Terminals | Suitable for up to 2.5mm2 cable |
Sensor type | Electroquímica |
Repeatability | +/- 2% FSD typically |
Zero drift | +/- 2% FSD, 6 months typically |
Response time | Contact Crowcon for a full list of sensor response times |
Performance | Tested in accordance with EN60079-29-1 |
Hazardous area zones | Zone 0, 1 or 2 Division 1 or 2 (when connected via an isolation device) |
Approvals | Ex II 1 G Ex ia IIC T4 (-40°C to +65°C) Exia IIC T4 Gb Tamb -20°C to +55°C UL Class I, groups A, B, C and D |
EMC compliance | EN 50270, FCC: CFR 47 Part 15, ICES-003 |
* Figures shown exclude the sensors – Please contact Crowcon for a full list of sensor operating temperatures
Gas | Range Available |
Ammonia (NH3) | 50, 100, 1000ppm |
Chlorine (Cl2) | 5, 10, 20ppm |
Carbon monoxide (CO) | 250, 500ppm |
Chlorine dioxide (ClO2) | 1ppm |
Hydrogen (H2) | 2000ppm, 50% LEL, 100% LEL |
Hydrogen cyanide (HCN) | 25ppm |
Hydrogen sulphide (H2S) | 25, 50, 100, 200ppm |
Hydrogen fluoride (HF) | 10ppm |
Nitrogen dioxide (NO2) | 10ppm |
Oxygen (O2) | 25% vol. |
Ozone (O3) | 1ppm |
Phosgene (COCl2) | 1ppm |
Phosphine (PH3) | 2ppm |
Sulphur dioxide (SO2) | 10, 20, 30ppm |
accesorios
Spray deflector C01338
For outdoor installations and protection from water sprays, for example in water treatment or food processing plants. Includes accessory adaptor….
Flow adaptor C01339
For applications where gas is being sampled via a pipe or tube.
Stainless steel duct mounting plate 00027D
For GRP junction boxes. Maximum duct airflow: 6 metres per second. Use TXgard-IS+ detector with side-entry.
Calibration adaptor C03005
To enable calibration gas to be applied to the detector. One adaptor can be used for several detectors.
Cable gland M02025
M20 Nylon. Fits Txgard-IS cable entries.
DOwnloads
Explorar productos relacionados
Subscribe to get the latest insights
IN your inbox
Read about Crowcon’s Privacy and Cookie policy here. If you change your mind, you can unsubscribe at any time