GASMAN
The Gasman is a compact, lightweight and highly durable single-gas detector, designed for use in the toughest environments. Perfect for customers who need more sensor options, TWA and data capability.
Wo man kaufen kannAvailable with a choice of sensor technology to suit your needs, the Gasman is an ultra-lightweight single gas detector, designed for use in the toughest environments. Its compact and lightweight design makes it the ideal choice for industrial gas detection, in oil and gas, chemical plants (with exotic gases), steel works (special CO sensor), hospitality (CO2), renewable energy (hydrogen) and waste and water works. Also available with our long-life O2 sensor (LLO2), for the accurate detection of oxygen depletion and enrichment, which comes with a 5 year warranty.
Weighing just 130g, it is extremely durable, with high impact resistance and dust/water ingress protection, loud 95 dB alarms, a vivid red/ blue visual warning, single-button control and an easy-to-read, backlit LCD display for clear insights and warnings. Data and event logging are available as standard, and there is a built-in 30-day advance warning when calibration is due. Gasman is also available in a safe area CO2 version offering 0-5% carbon dioxide measurement.
5-year sensor warranty
Ultra lightweight
One button operation
MPS™ & LLO2 sensor options
Interchangeable intelligent sensor modules
Robust
- Tough polycarbonate housing – protects you in the harshest environments
- Water and dust resistant to IP65
- Full over moulding – high impact resistance
Effective Warning
- Two levels of instantaneous alarm and time-weighted average (TWA) alarms for toxic versions
- 95dB audible alarm for loud, clear warnings even in noisy environments, ensuring you can respond quickly to hazards
- Vivid twin red/blue LED visual alarm for visibility of any warning
- Where ambient noise is high, a vibrating alarm is triggered, to guarantee awareness when on your person
Flexible
- Fully interchangeable intelligent sensor modules for precise, single-gas detection
- Real-time TWA and peak display options
- Rechargeable versions for all gas types
- Non-rechargeable versions providing an affordable solution for detection of oxygen and toxic gases
User Friendly
- Simple single-button operation making it easy-to-use even whilst wearing gloves
- Backlit display for easy reading of gas diagnostics and operating status, even in poorly lit conditions
- Weighing just 85g for toxic gas detection versions, it’s ultra lightweight making it no bother to carry at all times
Size | 90 x 48 x 24 mm (3.5 x 1.9 x 0.95 ins) |
Weight | Flammable: 138g (4.9oz) Toxic: 85g (3oz) Oxygen: 129g (4.6oz) Carbon monoxide: 139g (4.9oz) |
Typical response times (T90) | Flammable: 20s Flammable (MPS): 17s Toxic gas: 20s Oxygen: 10s Oxygen (Long-Life): 10s |
Alarms | Audible: 95dB; Multiple alarm options let you select distinctive tones for different alarm levels Visible: Dual colours red/ blue flashing LEDs in a gas hazard Internal vibrating alarm |
Display | Custom LCD with backlight, with display of gas concentration. Graphic symbols for battery (with proportional indication of remaining operation time), and display mode. Start up indication when calibration is due within 30 days, calibration overdue or service required. Normal display: Real time gas concentration levels Display recall: Peak readings and TWA |
Data logging | Full timed datalogging with adjustable sample rate, set to 1 min. data rate as default. 900 hours storage at 1 min. interval (54,000 logs), >4800 events |
Battery | Rechargeable lithium battery for all gas types Non-rechargeable lithium battery for toxics and oxygen (excluding CO2) |
Operating time* | Rechargeable with MPS: >3days Rechargeable: 12 hours minimum for flammable unit Non-rechargeable: Up to 2 years |
Sampling | Optional manual aspirator |
Operating temperature** | -20°C to +65°C (-4°F to +149°F) |
Humidity | 5 – 95% RH 0 to 99% RH (O2 LL MPS) |
Ingress protection | IP65 |
Approvals | Europe: Toxic or O2: ATEX II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +65°C) BASEEFA04ATEX0384 Flammable: ATEX II 2G Ex ia db IIC T4 Gb (-20°C ≤ Ta ≤ +65°C) BASEEFA04ATEX0383Flammable (MPS): ATEX II 1G Ex ia IIC T4 Ga (-20°C ≥Ta ≥ +65°C) BASEEFA04ATEX0383 International: Toxic or O2: IECEx Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +65°C) BAS05.0039 Flammable: IECEx Ex db ia IIC T4 Gb (-20°C ≤ Ta ≤ +65°C) BAS05.0038 North America: CSA Class 1 Groups A,B,C,D Division 1 |
Standards | Europe: EN60079-0, EN60079-11, EN60079-1, ATEX 2014/34/EU North America: CSA22.2, 152EN50270, EN50271, EN61779 |
PC Interface | RS232 connection from interface module in charger RS232/USB converter available |
Calibration | Gasman can be routinely calibrated using Portables PC software or by using Checkbox IMH |
Zubehör |
Gasman is supplied with an integral alligator clip. Optional accessories: Gas test kit, Gasman external filter, leather carry case, single way charger, charger interface software and communication kit (excluding PSU), 5 way multi-charger |
Crowcon Connect Compatible? | Yes |
*Operating time will depend on operating pattern and alarm occurrence. Frequent or long lasting alarms and use of the optional confidence beep will reduce battery life.
**Toxic and oxygen sensors are not rated for continuous operation at high temperatures. Consult Crowcon if operating temperatures are likely to exceed 40°C (104°F) for extended periods.
Required ranges and alarms vary by country and application and these can be configured as required. Each gas channel can have two instantaneous alarm levels set. Toxic units also have Time Weighted Average (TWA) alarms.
Flammable gas calibration is available for methane, propane, butane, pentane, hydrogen and
ethylene as standard.
Gasman is also available in a safe area CO2 version offering 0-5% carbon dioxide measurement.
Gas | Range | Standard Alarm (UK) |
Ammonia (NH3) | 0-1000 ppm | 25 ppm |
Kohlenmonoxid (CO) | 0-1500 ppm | 20 ppm |
Carbon Dioxide (CO2) | 0-5% vol. | 0.5% vol. |
Carbon Monoxide (H2 filtered) |
0-500ppm | 20ppm |
Chlorine (Cl2) | 0-20 ppm | 0.3 ppm |
Chlorine Dioxide (CIO2) | 0-1 ppm | 0.1 ppm |
Ethylene Oxide (ETO) | 0-10 ppm | 3 ppm |
Flammable True LEL (MPS) | 0-100% LEL | 20% LEL |
Flammable | 0 – 100% LEL | 20% LEL |
Fluorine (F2) | 0-1 ppm | 0.5 ppm |
Hydrogen (H2) | 0-2000 ppm | N/A |
Hydrogen Cyanide (HCN) | 0-25 ppm | 5 ppm |
Hydrogen Fluoride (HF) | 0-10 ppm | 1 ppm |
Hydrogen Sulphide (H2S) | 0-250ppm | 5 ppm |
Nitric Oxide (NO) | 0-100 ppm | 25 ppm |
Nitrogen Dioxide (NO2) | 0-20 ppm | 1 ppm |
Oxygen (O2), Long-Life | 0-25% vol. | 19.5% / 23.5% vol. |
Oxygen (O2) | 0-25% vol. | 19.5% / 23.5% vol. |
Ozone (O3) | 0-1 ppm | 0.1 ppm |
Phosphine (PH3) | 0-5 ppm | 0.1 ppm |
Phosgene (COCL2) | 0-1 ppm | 0.1 ppm |
Sulphur Dioxide (SO2) | 0-20 ppm | 1 ppm |
accessories
Gasman External Filter C02132
For use in high dust environments such as steel plants.
Leather carry case C01983
Enables unit to be worn either on a belt or with a shoulder strap.
Gas test kit C01892
Allows calibration and gas testing. Includes – Trigger regulator with 1m gas supply tube, flow cap, magnet and 2m gas…
Single Way Charger C01941
Charger cradle. Select power supply option.
Charging lead for vehicle lighter socket C01296
Use with 12V DC input charger cradles C01941 or C01940.
Gasman interface kit C011305
Gasman Interface Kit includes single way charger/interface, USB-RS232 adaptor, PC lead and multi-region PSU
5 Way Multi-Charger C01951
To recharge 5 Gasman units at once. Select power supply option.
Single Way PC Interface Charger C01940
Charger cradle with PC interface connection to allow data download and instrument configuration. Requires F-F PC lead (E07532) and either…
DOWNLOADS
Videos
Home screen
Includes: What the Gasman Home Screen looks like and understanding the icons. Duration: 28 seconds
Backlight
Includes: How to activate the backlight for viewing in poor lighting conditions. Duration: 19secs
Gasman Field Calibration
Includes: How to calibrate the Crowcon Gasman using a flow plate. Duration: 1m:57secs
Gasman CO Activation
Includes: Switching Gasman CO on and sensor zero function. Duration: 52secs
TWA
Includes: How to view average gas exposure measurements on a Gasman (TWA = Time Weighted Average). Duration: 46secs
Gasman Manual Zero
Includes: How to perform a sensor zero when in clean air. Duration: 50secs
Gasman Peak Mode
Includes: How to switch the display to show peak gas level readings. Duration: 31secs
Explore Related products
Subscribe to get the latest insights
in your inbox
Lesen Sie über Crowcon's Datenschutz und Cookie-Richtlinie hier. Wenn Sie Ihre Meinung ändern, können Sie sich jederzeit abmelden